{"id":1889,"date":"2023-05-24T11:43:26","date_gmt":"2023-05-24T03:43:26","guid":{"rendered":"https:\/\/www.hceics.com\/?page_id=1889"},"modified":"2023-05-24T11:47:06","modified_gmt":"2023-05-24T03:47:06","slug":"st-st8500-programmable-power-line-communication-p","status":"publish","type":"page","link":"https:\/\/www.hceics.com\/pt_br\/applications\/general-application\/st-st8500-programmable-power-line-communication-p\/","title":{"rendered":"ST ST8500 programmable power line communication (P"},"content":{"rendered":"<section class=\"section\" id=\"section_1185959111\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-706572202\">\n\n\t<div id=\"col-1345699084\" class=\"col dlemo-page-sidebar medium-3 small-12 large-3\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<div class=\"container section-title-container\" ><h3 class=\"section-title section-title-normal\"><b><\/b><span class=\"section-title-main\" style=\"color:rgb(2, 106, 180);\">FORMUL\u00c1RIOS<\/span><b><\/b><\/h3><\/div>\n\n\t<div class=\"ux-menu stack stack-col justify-start sidebar-nav spec-menu\">\n\t\t\n\n\t<div class=\"ux-menu-link flex menu-item\">\n\t\t<a class=\"ux-menu-link__link flex\" href=\"https:\/\/www.hceics.com\/pt_br\/applications\/enterprise-applications\/\"  >\n\t\t\t\t\t\t<span class=\"ux-menu-link__text\">\n\t\t\t\tAPLICA\u00c7\u00d5ES ENTERPRISE\t\t\t<\/span>\n\t\t<\/a>\n\t<\/div>\n\t\n\n\t<div class=\"ux-menu-link flex menu-item\">\n\t\t<a class=\"ux-menu-link__link flex\" href=\"https:\/\/www.hceics.com\/pt_br\/applications\/general-application\/\"  >\n\t\t\t\t\t\t<span class=\"ux-menu-link__text\">\n\t\t\t\tAPLICA\u00c7\u00c3O GERAL\t\t\t<\/span>\n\t\t<\/a>\n\t<\/div>\n\t\n\n\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-598010025\" class=\"col medium-9 small-12 large-9\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n  <div id=\"page-header-1853057205\" class=\"page-header-wrapper\">\n  <div class=\"page-title dlemo-inner-bread light simple-title\">\n\n    \n    <div class=\"page-title-inner container align-center flex-row medium-flex-wrap\" >\n              <div class=\"title-wrapper flex-col text-left medium-text-center\">\n          <h1 class=\"entry-title mb-0\">\n            ST ST8500 programmable power line communication (P          <\/h1>\n        <\/div>\n                    <div class=\"title-content flex-col flex-right text-right medium-text-center\">\n        <div class=\"title-breadcrumbs pb-half pt-half\"><nav class=\"woocommerce-breadcrumb breadcrumbs uppercase\" data-no-translation=\"\" data-trp-gettext=\"\">Home<\/nav><\/div>      <\/div>\n    <\/div>\n\n       <\/div>\n    <\/div>\n  \n<p>ST\u516c\u53f8\u7684ST8500\u53ef\u7f16\u52a8\u529b\u7ebf\u901a\u4fe1(PLC)\u8c03\u5236\u89e3\u8c03\u5668\u7cfb\u7edf\u7247\u4e0a\u7cfb\u7edf(SoC),\u80fd\u5728\u9891\u7387\u9ad8\u8fbe500kHz\u8fd0\u884c\u4efb\u4e00\u79cdPLC\u534f\u8bae.\u5668\u4ef6\u67b6\u6784\u8bbe\u8ba1\u7528\u4e8eCENELEC EN50065, FCC\u548cARIB\u517c\u5bb9\u7684\u5e94\u7528\u5175,\u652f\u6301\u6240\u6709\u4e3b\u8981\u7684PLC\u6807\u51c6\u5982ITU G.9904(PRIME),ITU G.9903 (G3-PLC\u00ae)\u4ee5\u53ca\u5176\u5b83PLC\u534f\u8bae\u89c4\u8303\u548c\u6f14\u8fdb.\u5668\u4ef6\u5305\u62ec\u5177\u6709\u81ea\u52a8<a href=\"http:\/\/www.eccn.com\/topic\/tag_list.html?id=6926&amp;index=6\" target=\"_blank\" rel=\"noopener\">\u589e\u76ca\u63a7\u5236<\/a>\u7684PGA\u548cADC,\u5177\u6709\u53d1\u9001\u9884\u9a71\u52a8\u5668\u7684DAC,\u6570\u5b57\u53d1\u9001\u7535\u5e73\u63a7\u5236,\u4ee5\u53ca\u96f6\u4ea4\u53c9\u6bd4\u8f83\u5668.\u9ad8\u8fbe500kHz\u7684PLC\u4fe1\u53f7\u5e26\u5bbd. ST8500\u5177\u6709\u6807\u51c632\u4f4dARM\u00ae Cortex-M4FMCU\u53ef\u7f16\u6838,\u7528\u4e8e\u534f\u8bae\u4e0a\u5c42\u548c\u5916\u8bbe\u7ba1\u7406,\u6700\u5927\u5de5\u4f5c\u9891\u7387200MHz,\u5d4c\u5165\u7528\u4e8e\u4ee3\u7801\u548c\u6570\u636e256kB\u7684SRAM,\u5d4c\u516596kB\u6570\u636eSRAM,8kB\u5171\u4eabRAM\u548c\u5f15\u5bfcROM<a href=\"http:\/\/www.eccn.com\/technology\/index_c.html?id=100010\" target=\"_blank\" rel=\"noopener\">\u5b58\u50a8\u5668<\/a>.\u5916\u63a53.3V\u7528\u4e8eI\/O\u548c\u6a21\u62df\u7535\u6e90,2.5V\u5185\u90e8\u7ebf\u6027\u7a33\u538b\u5668\u7528\u4e8e\u6a21\u62df,1.1V\u5916\u63a5\u7535\u6e90\u7528\u4e8e\u6570\u5b57,\u5177\u6709\u6b63\u5e38,\u6162,\u6253\u76f9\u548c\u4f4e\u529f\u8017\u6a21\u5f0f,\u91c7\u7528QFN56\u5c01\u88c5,\u5de5\u4f5c\u6e29\u5ea6-40\u2103 \u5230 +105\u2103.\u4e3b\u8981\u7528\u4e8e\u667a\u80fd\u8ba1\u91cf,\u667a\u80fd\u7535\u7f51\u548c\u7269\u8054\u7f51(IoT),\u4ee5\u53caCENELEC, FCC\u4e0eARIB\u517c\u5bb9\u7684\u5e94\u7528\u8bbe\u8ba1.\u672c\u6587\u4ecb\u7ecd\u4e86ST8500\u4e3b\u8981\u7279\u6027,\u57fa\u672c\u6846\u56fe\u548c\u8be6\u7ec6\u67b6\u6784\u56fe,\u65f6\u949f\u6811\u548c\u7535\u6e90\u65b9\u6848,\u4ee5\u53ca\u8bc4\u4f30\u677fEVALKITST8500-1\u4e3b\u8981\u7279\u6027,\u6846\u56fe\u548c\u7535\u8def\u56fe.<\/p>\n<p>Programmable power line communication modem System on Chip evaluation kit The ST8500 is a fully programmable power line communication (PLC) modem System on Chip (SoC), able to run any PLC\u00a0<a title=\"proto\" href=\"http:\/\/www.eccn.com\/topic\/tag_list.html?id=40508\" target=\"_blank\" rel=\"noopener\">proto<\/a>col in the\u00a0<a href=\"http:\/\/www.eccn.com\/topic\/tag_list.html?id=20158&amp;index=7\" target=\"_blank\" rel=\"noopener\">frequency<\/a>\u00a0band up to 500 kHz.<\/p>\n<p>The device architecture has been designed to target CENELEC EN50065, FCC and ARIB compliant applications supporting all major PLC protocol standards such as ITU G.9904(PRIME), ITU G.9903 (G3-PLC\u00ae) and many other possible PLC protocol specifications andevolutions.<\/p>\n<p><strong>ST8500\u4e3b\u8981\u7279\u6027:<\/strong><\/p>\n<p>\uf0b7 Programmable power line communication(PLC) modem System on Chip<br \/>\n\uf0b7 Integrated differential PLC analog front-end<br \/>\n\u2013 PGA with automatic gain control and ADC<br \/>\n\u2013 DAC with transmission pre-driver<br \/>\n\u2013 Digital transmission level control<br \/>\n\u2013 Zero crossing comparator<br \/>\n\u2013 Up to 500 kHz PLC signal bandwidth<br \/>\n\uf0b7 High performance, fully programmable realtimeengine dedicated to PLC PHY and real -time MAC protocol management (400 MHzmax. frequency)<br \/>\n\u2013 Dedicated code and data SRAM memories<br \/>\n\uf0b7 Standard ARM\u00ae 32-bit Cortex\u00ae-M4F fullyprogrammable core for protocol upper layers<br \/>\nand peripherals management<br \/>\n\u2013 200 MHz maximum frequency<br \/>\n\u2013 256 kB of embedded SRAM for code anddata<br \/>\n\u2013 96 kB of embedded SRAM for data<br \/>\n\u2013 8 kB of embedded shared RAM<br \/>\n\u2013 Bootloader ROM memory<br \/>\n\u2013 One Time Programmable (OTP) memorywith dedicated areas available for secure<br \/>\nkeys and user information storage<br \/>\n\u2013 Serial wire and JTAG interfaces<br \/>\n\u2013 24 multiplexed GPIOs<br \/>\n\u2013 4 general purpose timers<br \/>\n\u2013 1 flexible CRC calculation unit<br \/>\n\u2013 2 USART, 1 UART, 3 SPI, 1 I2C<br \/>\n\uf0b7 Cryptographic engine<br \/>\n\u2013 AES 128\/192\/256 engine<br \/>\n\u2013 True random number generator<br \/>\n\u2013 Pseudo random number generator<br \/>\n\uf0b7 Clock management:<br \/>\n\u2013 25 MHz external crystal for system clock<br \/>\n\u2013 Integrated 25 MHz oscillator (XOSC) withfrequency synthesizer (FS) and pre-<a href=\"http:\/\/www.eccn.com\/topic\/tag_list.html?id=43962\" target=\"_blank\" rel=\"noopener\">sca<\/a>ler<br \/>\nunits to generate internal clock signals<br \/>\n\uf0b7 Power management<br \/>\n\u2013 3.3 V external supply voltage for I\/O andanalog<br \/>\n\u2013 2.5 V internal linear regulator for analog<br \/>\n\u2013 1.1 V external supply voltage for digital<br \/>\n\u2013 Normal, Slow, Doze and low power modes<br \/>\n\uf0b7 Available in QFN56 package<br \/>\n\uf0b7 -40\u2103 to +105\u2103 temperature range<\/p>\n<p><strong>ST8500\u5e94\u7528:<\/strong><\/p>\n<p>\uf0b7 Smart metering, smart grid and Internet ofThings applications<br \/>\n\uf0b7 Suitable for application design compliant withCENELEC, FCC and ARIB regulations<br \/>\nThe ST8500 architecture is composed of the following parts:<br \/>\n1. PLC front-end including digital front-end (DFE) and analog front-end (AFE)<br \/>\n2. Real-time engine: the digital core running the lower layers of the PLC protocol stack<br \/>\nand implementing modulation, demodulation and advanced forward error corrections(FEC) algorithms<br \/>\n3. Protocol engine: the digital core running the upper layers of the PLC protocol stack and<br \/>\nmanaging the interface with external microcontrollers.<br \/>\n4. Peripherals, crypto, debug section<br \/>\n5. Clock and reset section<br \/>\n6. Power management section<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112259448.png\" width=\"476\" height=\"338\" \/><br \/>\n\u56fe1.ST8500\u57fa\u672c\u6846\u56fe<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112259770.png\" width=\"473\" height=\"424\" \/><br \/>\n\u56fe2.ST8500\u8be6\u7ec6\u67b6\u6784\u56fe<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/2019120511225959.png\" width=\"476\" height=\"319\" \/><br \/>\n\u56fe3.ST8500\u65f6\u949f\u6811\u56fe<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112259278.png\" width=\"476\" height=\"442\" \/><br \/>\n\u56fe4.ST8500\u7535\u6e90\u65b9\u6848\u56fe<\/p>\n<p><strong>\u8bc4\u4f30\u677fEVALKITST8500-1<\/strong><\/p>\n<p>The EVALKITST8500-1 is a platform which allows an easy way to evaluate the features andperformance of a power line communication (PLC) node based on the ST8500 modemsystem-on-chip and the STLD1 line driver.<\/p>\n<p>This user manual explains the EVALKITST8500-1 hardware and software installation, and<br \/>\ndetails the evaluation of the kits.<\/p>\n<p>This user manual does not explain the functionalities of the various PLC protocols running<br \/>\non the ST8500. Detailed information can be found in the protocol specific documentation,<br \/>\navailable within the software packages, separately delivered under the Software license<br \/>\nagreement by contacting your local ST sales office.<\/p>\n<p>Based on the ST8500 power line communication System on Chip, the EVALKITST8500-1 evaluation kit embeds all the functions required for a turnkey power line communication network.<\/p>\n<p>Depending on the PLC protocol targeted, different firmware releases should be loaded on the host Flash memory. Please check software release availability with your local STMicroelectronics sales office.<\/p>\n<p>Intuitive graphical user interface (GUI) for the Windows<sup>\u00ae<\/sup>\u00a0environment allows the user to upgrade the firmware release, configure and control the evaluation kit.<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112259185.png\" width=\"418\" height=\"218\" \/><br \/>\n\u56fe5.\u8bc4\u4f30\u677fEVALKITST8500-1\u5916\u5f62\u56fe<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112259186.png\" width=\"476\" height=\"193\" \/><br \/>\n\u56fe6.\u8bc4\u4f30\u677fEVALKITST8500-1\u6846\u56fe<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112259151.png\" width=\"473\" height=\"139\" \/><br \/>\n\u56fe7.STM32\u63a7\u5236\u677f\u5916\u5f62\u56fe<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112300832.png\" width=\"476\" height=\"223\" \/><br \/>\n\u56fe8.STM32\u63a7\u5236\u677f\u6982\u51b5\u56fe<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112300998.png\" width=\"476\" height=\"176\" \/><br \/>\n\u56fe9.ST8500\u6a21\u5757\u5916\u5f62\u56fe<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112300903.png\" width=\"473\" height=\"253\" \/><br \/>\n\u56fe10.ST8500\u6a21\u5757\u6982\u51b5\u56fe<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112300241.png\" width=\"554\" height=\"387\" \/><br \/>\n\u56fe11.\u8bc4\u4f30\u677fEVALKITST8500-1\u7535\u8def\u56fe:EVALST-PLCMB1(1)<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112300175.png\" width=\"554\" height=\"387\" \/><br \/>\n\u56fe12.\u8bc4\u4f30\u677fEVALKITST8500-1\u7535\u8def\u56fe:EVALST-PLCMB1(2)<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112300607.png\" width=\"554\" height=\"386\" \/><br \/>\n\u56fe13.\u8bc4\u4f30\u677fEVALKITST8500-1\u7535\u8def\u56fe:PSU_VIPER\u677f<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112300268.png\" width=\"554\" height=\"388\" \/><br \/>\n\u56fe14.\u8bc4\u4f30\u677fEVALKITST8500-1\u7535\u8def\u56fe:ST8500\u6a21\u5757\u677f(1)<br \/>\n<img loading=\"lazy\" src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/20191205112300796.png\" width=\"554\" height=\"388\" \/><br \/>\n\u56fe15.\u8bc4\u4f30\u677fEVALKITST8500-1\u7535\u8def\u56fe:ST8500\u6a21\u5757\u677f(2)<br \/>\n\u8be6\u60c5\u8bf7\u89c1:<br \/>\n<a href=\"https:\/\/www.st.com\/content\/ccc\/resource\/technical\/document\/user_manual\/group0\/3a\/dc\/89\/3e\/4d\/6d\/46\/d1\/DM00467734\/files\/DM00467734.pdf\/jcr:content\/translations\/en.DM00467734.pdf\">https:\/\/www.st.com\/content\/ccc\/resource\/technical\/document\/user_manual\/group0\/3a\/dc\/89\/3e<br \/>\n\/4d\/6d\/46\/d1\/DM00467734\/files\/DM00467734.pdf\/jcr:content\/translations\/en.DM00467734.pdf<\/a><br \/>\n<img src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/pdf-27.gif\" border=\"0\" \/><a href=\"http:\/\/solution.eccn.com\/uploads\/solution\/201912\/20191205113041534.pdf\" target=\"_blank\" rel=\"noopener\">st8500.pdf<\/a><br \/>\n<img src=\"https:\/\/www.hceics.com\/wp-content\/uploads\/pdf-27.gif\" border=\"0\" \/><a href=\"http:\/\/solution.eccn.com\/uploads\/solution\/201912\/20191205113116897.pdf\" target=\"_blank\" rel=\"noopener\">en.DM00467734.pdf<\/a><\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1185959111 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n#section_1185959111 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_1185959111 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":1869,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.hceics.com\/pt_br\/wp-json\/wp\/v2\/pages\/1889"}],"collection":[{"href":"https:\/\/www.hceics.com\/pt_br\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hceics.com\/pt_br\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hceics.com\/pt_br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hceics.com\/pt_br\/wp-json\/wp\/v2\/comments?post=1889"}],"version-history":[{"count":0,"href":"https:\/\/www.hceics.com\/pt_br\/wp-json\/wp\/v2\/pages\/1889\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.hceics.com\/pt_br\/wp-json\/wp\/v2\/pages\/1869"}],"wp:attachment":[{"href":"https:\/\/www.hceics.com\/pt_br\/wp-json\/wp\/v2\/media?parent=1889"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}